Skip to main content

Research Repository

Advanced Search

A New Paramagnetically Shifted Imaging Probe for MRI

Senanayake, P.K.; Rogers, N.J.; Harvey, P.; Finney, K.L.N.A.; Funk, A.M.; Wilson, J.I.; Maxwell, R.; Blamire, A.M.; Parker, D.

A New Paramagnetically Shifted Imaging Probe for MRI Thumbnail


Authors

P.K. Senanayake

N.J. Rogers

P. Harvey

K.L.N.A. Finney

A.M. Funk

J.I. Wilson

R. Maxwell

A.M. Blamire



Abstract

Purpose: To develop and characterize a new paramagnetic contrast agent for molecular imaging by MRI. Methods: A contrast agent was developed for direct MRI detection through the paramagnetically shifted proton magnetic resonances of two chemically equivalent tert-butyl reporter groups within a dysprosium(III) complex. The complex was characterized in phantoms and imaged in physiologically intact mice at 7 Tesla (T) using three-dimensional (3D) gradient echo and spectroscopic imaging (MRSI) sequences to measure spatial distribution and signal frequency. Results: The reporter protons reside ∼6.5 Å from the paramagnetic center, resulting in fast T1 relaxation (T1 = 8 ms) and a large paramagnetic frequency shift exceeding 60 ppm. Fast relaxation allowed short scan repetition times with high excitation flip angle, resulting in high sensitivity. The large dipolar shift allowed direct frequency selective excitation and acquisition of the dysprosium(III) complex, independent of the tissue water signal. The biokinetics of the complex were followed in vivo with a temporal resolution of 62 s following a single, low-dose intravenous injection. The lower concentration limit for detection was ∼23 μM. Through MRSI, the temperature dependence of the paramagnetic shift (0.28 ppm.K−1) was exploited to examine tissue temperature variation. Conclusions: These data demonstrate a new MRI agent with the potential for physiological monitoring by MRI. Magn Reson Med 77:1307–1317, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Citation

Senanayake, P., Rogers, N., Harvey, P., Finney, K., Funk, A., Wilson, J., …Parker, D. (2017). A New Paramagnetically Shifted Imaging Probe for MRI. Magnetic Resonance in Medicine, 77(3), 1307-1317. https://doi.org/10.1002/mrm.26185

Journal Article Type Article
Acceptance Date Feb 5, 2016
Online Publication Date Feb 28, 2016
Publication Date Mar 1, 2017
Deposit Date Mar 2, 2017
Publicly Available Date Mar 3, 2017
Journal Magnetic Resonance in Medicine
Print ISSN 0740-3194
Electronic ISSN 1522-2594
Publisher Wiley
Peer Reviewed Peer Reviewed
Volume 77
Issue 3
Pages 1307-1317
DOI https://doi.org/10.1002/mrm.26185

Files

Published Journal Article (4.4 Mb)
PDF

Publisher Licence URL
http://creativecommons.org/licenses/by/4.0/

Copyright Statement
© 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.





You might also like



Downloadable Citations