Studies demonstrate that the power converter has one of the highest failure rates in a wind turbine, with a key failure driver being the power module junction temperature ( T j ). This paper details an experimental setup for simplified emulation of wind turbine conditions on a power converter with infra-red sensing of IGBT T j . Results are compared to previous simulation work for a PMSG wind turbine, with the same trend of increasing mean T j with wind speed found, and the need to use an equivalent generator reactance in highlighted. A commercial-scale prototype for more accurate wind turbine converter emulation is also detailed.
Citation
Smith, C., Zappalá, D., Crabtree, C., Lapiedra, J., & Mulholland, B. (2019). Power Converter Junction Temperature Measurement using Infra-red Sensors. Journal of Engineering, 2019(17), 4452-4456. https://doi.org/10.1049/joe.2018.8098
Journal Article Type | Article |
---|---|
Acceptance Date | Aug 2, 2018 |
Online Publication Date | Jan 22, 2019 |
Publication Date | Jun 30, 2019 |
Deposit Date | Aug 28, 2018 |
Publicly Available Date | Sep 12, 2018 |
Journal | Journal of Engineering |
Publisher | Institution of Engineering and Technology (IET) |
Peer Reviewed | Peer Reviewed |
Volume | 2019 |
Issue | 17 |
Pages | 4452-4456 |
DOI | https://doi.org/10.1049/joe.2018.8098 |
Public URL | https://durham-repository.worktribe.com/output/1350544 |
Files
Accepted Journal Article
(2.2 Mb)
PDF
Publisher Licence URL
http://creativecommons.org/licenses/by/3.0/
Copyright Statement
This is an open access article published by the IET under the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/)
Published Journal Article
(3 Mb)
PDF
Publisher Licence URL
http://creativecommons.org/licenses/by/3.0/
Published Journal Article (Advance online version)
(3 Mb)
PDF
Publisher Licence URL
http://creativecommons.org/licenses/by/3.0/
Copyright Statement
Advance online version
You might also like
Simplified Automatic Fault Detection in Wind Turbine Induction Generators
(2020)
Journal Article
Investigating wind turbine dynamic transient loads using contactless shaft torque measurements
(2018)
Conference Proceeding
Downloadable Citations
About Durham Research Online (DRO)
Administrator e-mail: dro.admin@durham.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search