Miland, H. and Glockner, R. and Taylor, P. and Aaberg, R. J. and Hagen, G. (2006) 'Load control of a wind-hydrogen stand-alone power system.', International journal of hydrogen energy., 31 (9). pp. 1215-1235.
Abstract
A new generation of load controllers enable stand-alone power systems (SAPS) to use one or many standard (grid connected) wind turbines. The controllers use fuzzy logic software algorithms. The strategy is to use the control loads to balance the flow of active power in the system and hence control system frequency. The dynamic supply of reactive power by a synchronous compensator maintains the system voltage within the limits specified in EN50160. The resistive controller loads produce a certain amount of heat that is exchanged down to the end user (hot water). It was decided to investigate the implementation of a hydrogen subsystem into the SAPS that can work in parallel with the Distributed Intelligent Load Controller (DILC). The hydrogen subsystem can then function as energy storage on long-term basis and an active load controller on short-term basis.
| Item Type: | Article |
|---|---|
| Keywords: | Hydrogen, Electrolyser, Fuel cell, Wind turbine, Load control. |
| Full text: | Full text not available from this repository. |
| Publisher Web site: | http://dx.doi.org/10.1016/j.ijhydene.2005.09.005 |
| Record Created: | 24 Oct 2006 |
| Last Modified: | 12 Feb 2010 12:32 |
Social bookmarking: ![]() ![]() ![]() ![]() | Export: EndNote, Zotero | BibTex |
| Usage statistics | Look up in GoogleScholar | Find in a UK Library |





![[Feed]](/images/RSSwebsmall.jpg)
![[Tweets]](/images/Twitterwebsmall.png)