Background: Stereoscopic assessment of the optic disc morphology is an important part of the care of patients with glaucoma. The aim of this study was to assess stereoviewing of stereoscopic optic disc images using an example of the new technology of autostereoscopic screens compared to the liquid shutter goggles. Methods: Independent assessment of glaucomatous disc characteristics and measurement of optic disc and cup parameters whilst using either an autostereoscopic screen or liquid crystal shutter goggles synchronized with a view switching display. The main outcome measures were inter-modality agreements between the two used modalities as evaluated by the weighted kappa test and Bland Altman plots. Results: Inter-modality agreement for measuring optic disc parameters was good [Average kappa coefficient for vertical Cup/Disc ratio was 0.78 (95% CI 0.62–0.91) and 0.81 (95% CI 0.6–0.92) for observer 1 and 2 respectively]. Agreement between modalities for assessing optic disc characteristics for glaucoma on a five-point scale was very good with a kappa value of 0.97. Conclusion: This study compared two different methods of stereo viewing. The results of assessment of the different optic disc and cup parameters were comparable using an example of the newly developing autostereoscopic display technologies as compared to the shutter goggles system used. The Inter-modality agreement was high. This new technology carries potential clinical usability benefits in different areas of ophthalmic practice.

Citation

Habib, M., Lowell, J., Holliman, N., Andrew Hunter, A., Vaideanu, D., Hildreth, A., & Steel, D. (2008). Assessment of stereoscopic optic disc images using an autostereoscopic screen. experimental study. BMC Ophthalmology, 8, Article 13. https://doi.org/10.1186/1471-2415-8-13

Journal Article Type Article
Publication Date Jul 23, 2008
Deposit Date Sep 16, 2010
Publicly Available Date May 29, 2012
Journal BMC Ophthalmology
Publisher BioMed Central
Peer Reviewed Peer Reviewed
Volume 8
Article Number 13
DOI https://doi.org/10.1186/1471-2415-8-13

Files





You might also like



Downloadable Citations