Skip to main content

Research Repository

Advanced Search

Reservoir depletion at The Geysers geothermal area, California, shown by four-dimensional seismic tomography

Gunasekera, R.C.; Foulger, G.R.; Julian, B.R.

Reservoir depletion at The Geysers geothermal area, California, shown by four-dimensional seismic tomography Thumbnail


Authors

R.C. Gunasekera

G.R. Foulger

B.R. Julian



Abstract

Intensive geothermal exploitation at The Geysers geothermal area, California, induces myriads of small-magnitude earthquakes that are monitored by a dense, permanent, local seismometer network. Using this network, tomographic inversions were performed for the three-dimensional Vp and Vp/Vs structure of the reservoir for April 1991, February 1993, December 1994, October 1996, and August 1998. The extensive low-Vp/Vs anomaly that occupies the reservoir grew in strength from a maximum of 9% to a maximum of 13.4% during the 7-year study period. This is attributed to depletion of pore liquid water in the reservoir and replacement with steam. This decreases Vp by increasing compressibility, and increases Vs because of reduction in pore pressure and the drying of argillaceous minerals, e.g., illite, which increase the shear modulus. These effects serendipitously combine to lower Vp/Vs, resulting in a strong overall effect that provides a convenient tool for monitoring reservoir depletion. Variations in the Vp and Vs fields indicate that water depletion is the dominant process in the central part of the exploited reservoir, and pressure reduction and mineral drying in the northwest and southeast parts of the reservoir. The rate at which the Vp/Vs anomaly grew in strength in the period 1991–1998 suggests most of the original anomaly was caused by exploitation. Continuous monitoring of Vp, Vs, and Vp/Vs is an effective geothermal reservoir depletion monitoring tool and can potentially provide information about depletion in parts of the reservoir that have not been drilled.

Citation

Gunasekera, R., Foulger, G., & Julian, B. (2003). Reservoir depletion at The Geysers geothermal area, California, shown by four-dimensional seismic tomography. Journal of Geophysical Research, 108(B3), Article 2134. https://doi.org/10.1029/2001jb000638

Journal Article Type Article
Publication Date Mar 7, 2003
Deposit Date Feb 26, 2015
Publicly Available Date Feb 27, 2015
Journal Journal of Geophysical Research. Solid Earth
Print ISSN 0148-0227
Publisher Wiley
Peer Reviewed Peer Reviewed
Volume 108
Issue B3
Article Number 2134
DOI https://doi.org/10.1029/2001jb000638
Keywords Geysers, Tomography, Four-dimensional, Geothermal, Reservoir, Depletion.

Files

Published Journal Article (799 Kb)
PDF

Copyright Statement
Gunasekera, R.C., Foulger, G.R. and Julian, B.R. (2003), Reservoir depletion at The Geysers geothermal area, California, shown by four-dimensional seismic tomography, Journal of Geophysical Research: Solid Earth, 108, 2134, 10.1029/2001JB000638 (DOI). To view the published open abstract, go to http://dx.doi.org and enter the DOI.




You might also like



Downloadable Citations