Cookies

We use cookies to ensure that we give you the best experience on our website. By continuing to browse this repository, you give consent for essential cookies to be used. You can read more about our Privacy and Cookie Policy.


Durham Research Online
You are in:

Reservoir depletion at The Geysers geothermal area, California, shown by four-dimensional seismic tomography.

Gunasekera, R.C. and Foulger, G.R. and Julian, B.R. (2003) 'Reservoir depletion at The Geysers geothermal area, California, shown by four-dimensional seismic tomography.', Journal of geophysical research : solid earth., 108 (B3). p. 2134.

Abstract

Intensive geothermal exploitation at The Geysers geothermal area, California, induces myriads of small-magnitude earthquakes that are monitored by a dense, permanent, local seismometer network. Using this network, tomographic inversions were performed for the three-dimensional Vp and Vp/Vs structure of the reservoir for April 1991, February 1993, December 1994, October 1996, and August 1998. The extensive low-Vp/Vs anomaly that occupies the reservoir grew in strength from a maximum of 9% to a maximum of 13.4% during the 7-year study period. This is attributed to depletion of pore liquid water in the reservoir and replacement with steam. This decreases Vp by increasing compressibility, and increases Vs because of reduction in pore pressure and the drying of argillaceous minerals, e.g., illite, which increase the shear modulus. These effects serendipitously combine to lower Vp/Vs, resulting in a strong overall effect that provides a convenient tool for monitoring reservoir depletion. Variations in the Vp and Vs fields indicate that water depletion is the dominant process in the central part of the exploited reservoir, and pressure reduction and mineral drying in the northwest and southeast parts of the reservoir. The rate at which the Vp/Vs anomaly grew in strength in the period 1991–1998 suggests most of the original anomaly was caused by exploitation. Continuous monitoring of Vp, Vs, and Vp/Vs is an effective geothermal reservoir depletion monitoring tool and can potentially provide information about depletion in parts of the reservoir that have not been drilled.

Item Type:Article
Keywords:Geysers, Tomography, Four-dimensional, Geothermal, Reservoir, Depletion.
Full text:(VoR) Version of Record
Download PDF
(781Kb)
Status:Peer-reviewed
Publisher Web site:http://dx.doi.org/10.1029/2001JB000638
Publisher statement:Gunasekera, R.C., Foulger, G.R. and Julian, B.R. (2003), Reservoir depletion at The Geysers geothermal area, California, shown by four-dimensional seismic tomography, Journal of Geophysical Research: Solid Earth, 108, 2134, 10.1029/2001JB000638 (DOI). To view the published open abstract, go to http://dx.doi.org and enter the DOI.
Date accepted:No date available
Date deposited:27 February 2015
Date of first online publication:March 2003
Date first made open access:No date available

Save or Share this output

Export:
Export
Look up in GoogleScholar